3
CONTENTS
GB
Installation
■
Positioning
■
Cleaning the interior
■
Rear spacers
■
Door reversibility
■
Electrical connection
Technical specification
Use
■
Operation
■
Temperature regulation
■
Fresh food refrigeration
■
Movable shelves
■
Positioning the door shelves
■
Freezing fresh food
■
Storage of frozen food
■
Thawing
■
Ice cube production
■
Defrosting
Maintenance
■
Periodic cleaning
■
Extended periods of non-operation
■
Interior light
Defective operation
4
4
4
4
4
4
5
5
5
6
6
6
5
5
6
6
7
9
8
8
8
8
2222 185-05
Printed on recycled paper
If this appliance featuring magnetic door seals
is to replace an older appliance having a
spring lock (latch) on the door or lid, be sure
to make that spring lock unusable before you
discard the old appliance. This will prevent it
from becoming a death-trap for a child.
Positioning
The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc. Best performance is obtained with
ambient temperature between +18°C and +43°C
(class T); +18°C and +38°C (class ST); +16°C
and +32°C (class N); +10°C and +32°C (class
SN). The class of your appliance is shown on
its rating plate.
Ensure that air can circulate freely around the
back of the cabinet. To ensure best performance,
if the appliance is positioned below an
overhanging wall unit, the minimum distance
between the top of the cabinet and the wall unit
must be at least 100 mm (Fig. 1). Ideally,
however, the appliance should not be positioned
below overhanging wall units . Accurate levelling
is ensured by one or more adjustable feet at the
base of the cabinet.
The Manufacturer declines all responsibility if
the above safety precautions are not
observed.
This appliance complies with EEC directive
number 87/308 of 2/6/87 relative to radio
interference suppression.
Important
It is essential that the appliance be connected to
an efficient earth tap. For this purpose the supply
cable plug incorporates a special earth contact. If
contact. If the sockets of your domestic wiring
system are not earthed, have the appliance
connected to a separate earth wire by a
qualified electrician in accordance with existing
safety regulations.
Rear spacers
In the bag with the documentation, there are
two spacers which must be fitted into the
special openings provided on the back of
the appliance.
Push-fit the spacers into the openings, making
sure that arrow (A) is positioned as per Fig. 2
and then turn the spacers through 45° until they
lock in (arrow in vertical position).
NP003
A
B
100 mm10 mm
10 mm
Fig. 1
INSTALLATION
GB
D039
A
45°
Fig. 2